An API Access licence is required to enable Print Audit integration. Please contact Readysell for more information.

Configuring Print Audit

  1. Log into your Print Audit Facilities Manager
  2. Navigate to Reporting > Data Exports
  3. Select the Device Inventory (XML) report template and proceed to next step
  4. Configure any grouping/filtering as required and proceed to next step
  5. Enter any report title and proceed to next step
  6. Select Schedule this report for future delivery and set a schedule
  7. Select Web Service for "Delivery Via"
  8. Set up the URL as https://SUBDOMAIN.readysell.com.au:8205/PlainServiceEndpoint/ReceivePrintAuditMessage (where SUBDOMAIN is the CUSTOMER-CODE - available in the Administration>Advanced>System Types then select "LICENSING" system type)

  9. Click Generate Report

Configuring Readysell

  1. In Readysell, navigate to Administration > Meter Types
  2. For the mono and colour meter types, set the "MPS Meter Name" to "LifeCountMono" or "LifeCountColor" respectively
  3. Navigate to RelationshipsCards
  4. For any card that you wish to integrate:
    1. Go to the Settings > Customer Settings > Web Integration
    2. Set the "MPS Account ID" to match the Print Audit Customer ID (visible in the URL, e.g. EditCustomer.aspx?id=79)
  5. Navigate to Service > Machines
  6. For any machine that you wish to integrate:
    1. Set the serial number to match the serial number in Print Audit
    2. Set the model on the associated product to match that in Print Audit

See also